BTU Calculator – Convert BTU, Size a Room AC, and Work Backwards
Convert BTU to kWh, watts, and tons of cooling, get a rule-of-thumb room AC size from square footage, or find out what room size a heater or fireplace can serve — with every constant shown.
What do you want to work out?
Rule-of-thumb sizing only: base 20 BTU per sq ft, plus 10 percent for a sunny room, plus 4,000 BTU for a kitchen, plus 600 BTU per person beyond the first two. Ceilings above 8 ft add 10 percent per extra foot. For a real purchase, get a Manual J professional calculation.
Private by design: every number is worked out in your browser. Nothing you type is sent anywhere or stored.
Your result
- The constants are locked: 1 kWh equals 3,412.14 BTU, and 1 ton of cooling equals 12,000 BTU per hour.
- Room sizing starts at 20 BTU per square foot — a rule of thumb, not an exact sizing; a real purchase needs a Manual J calculation.
- Rates and amounts are different things: BTU per hour, watts and tons are rates, while BTU and kWh are amounts of energy.
- The picture: your number on a scale
- Keep exploring
- How it works in three steps
- How the number is worked out
- Going deeper
- Five rooms, five sizes — and the adjustments that move them
- Rate versus energy: the distinction the whole page turns on
- Why 20 BTU per square foot is only a starting point
- Frequently asked questions
The picture: your number on a scale
The bar runs from 0 to 60,000 BTU per hour, the largest common residential size on this page. Your result fills it in orange, with the ton rating marked underneath.
At the defaults, a 500 sq ft room needs a rule-of-thumb 10,000 BTU per hour, which is under 1 ton of cooling.
Keep exploring
How it works in three steps
How the number is worked out
Unit conversion uses three fixed constants. 1 kWh = 3,412.14 BTU, 1 watt = 3.41214 BTU per hour, and 1 ton of cooling = 12,000 BTU per hour. So 10 kWh becomes 10 × 3,412.14 = 34,121 BTU, 1.5 tons becomes 1.5 × 12,000 = 18,000 BTU per hour, and 1,000 watts becomes 1,000 × 3.41214 = 3,412 BTU per hour. To go the other way, divide instead of multiplying: 34,121 BTU ÷ 3,412.14 = 10 kWh.
Room AC sizing is a rule-of-thumb estimate, not an exact sizing. Start with room area times 20 BTU per sq ft: a 500 sq ft room gives 500 × 20 = 10,000 BTU per hour. A sunny room multiplies that by 1.10 (11,000 BTU per hour for the same room), a kitchen adds 4,000 BTU per hour (14,000 for the same room), and each person beyond the first two adds 600 BTU per hour (11,200 for four people). Ceilings above 8 ft add 10 percent per extra foot, so the same 500 sq ft room with a 10 ft ceiling needs 12,000 BTU per hour. The page then rounds up to the nearest standard size from 5,000, 6,000, 8,000, 10,000, 12,000, 14,000, 18,000, 24,000, 28,000, 32,000, 36,000, 48,000, and 60,000 BTU per hour.
The inverse calculation divides instead of multiplying. Room area served equals heater BTU divided by BTU per sq ft. A 12,000 BTU unit serves 12,000 ÷ 20 = 600 sq ft on the cooling rule of thumb, but only 12,000 ÷ 50 = 240 sq ft on the cold-climate heating factor. A 30,000 BTU heater serves 1,000 sq ft at 30 BTU per sq ft and 600 sq ft at 50 BTU per sq ft. For a real purchase, get a Manual J professional calculation: insulation, windows, shading, and climate all move the true number away from any rule of thumb.
Going deeper
The 20 BTU per sq ft figure is a widely published rule of thumb for a typical room with standard ceilings and average insulation. It ignores the things that actually decide cooling load: how well the room is insulated, how big and sun-facing the windows are, how many heat-producing appliances run in it, and how hot the local climate gets. Two 500 sq ft rooms can honestly need sizes thousands of BTU apart. Use this page to narrow the range, then let a professional Manual J calculation settle the purchase — oversizing wastes energy and short-cycles, and undersizing never catches up on a hot day.
BTU and kWh measure amounts of energy; BTU per hour, watts, and tons measure rates, or how fast energy moves. A 12,000 BTU per hour air conditioner running for one hour moves 12,000 BTU, which is about 3.52 kWh of cooling. This page converts the numbers between all four units and labels rate results per hour, so a watt figure always means watts of cooling power, not energy used. When a bill talks about kWh, it means energy over time; when a unit label talks about BTU or tons, it means the rate it can sustain.
Five rooms, five sizes — and the adjustments that move them
Every figure below was run through the calculator above, starting from its default room — 500 square feet, 8-foot ceilings, two people, no sun, no kitchen — and changing one thing at a time. All sizing figures are rule-of-thumb estimates, not exact sizings: the page starts from 20 BTU per square foot and adjusts from there, and for a real purchase it insists on a Manual J professional calculation. The adjustments are listed separately in the breakdown, so each one can be seen doing its own work.
| What changed | Computed size | Nearest standard size |
|---|---|---|
| Default: 500 sq ft, 8 ft ceiling, 2 people | 10,000 BTU/h | 10,000 BTU/h (0.83 tons) |
| Sunny room (lots of direct sun) | 11,000 BTU/h | — |
| Kitchen (cooking heat) | 14,000 BTU/h | — |
| Ceiling raised to 10 ft | 12,000 BTU/h | — |
| Four people instead of two | 11,200 BTU/h | 12,000 BTU/h (0.93 tons) |
| Room doubled to 1,000 sq ft | 20,000 BTU/h | — |
The default row is the whole method in one line: 500 × 20 = 10,000 BTU per hour. Each adjustment then has its own rule, from the page’s own worked guidance. A sunny room multiplies the base by 1.10, taking the same room to 11,000 BTU per hour. A kitchen adds a flat 4,000 BTU per hour, taking it to 14,000 — the single largest adjustment on the page, because cooking heat is a large, steady load that area alone cannot see. Ceilings above 8 feet add 10 percent per extra foot, so the same room with a 10-foot ceiling needs 12,000 BTU per hour: two extra feet at 10 percent each on the 10,000 base. Each person beyond the first two adds 600 BTU per hour, so four people give 11,200 — the base 10,000 plus two extra people at 600 each. And doubling the room doubles the base: 1,000 square feet at 20 BTU per square foot is 20,000 BTU per hour, before any adjustment.
The nearest-standard-size rows deserve attention, because they show the last step of the page’s logic. Standard sizes on this page run from 5,000 through 6,000, 8,000, 10,000, 12,000, 14,000, 18,000, 24,000, 28,000, 32,000, 36,000, 48,000 and 60,000 BTU per hour, and the computed figure is rounded up to the nearest of them. The default 10,000 is already a standard size, so it stays 10,000 (0.83 tons, since one ton is 12,000 BTU per hour). The four-person case computes 11,200, which is not a standard size, so it rounds up to 12,000 (0.93 tons) — up, never down, because an air conditioner slightly larger than the estimate still cools the room, while one slightly smaller does not on the hottest day. Rounding down to 10,000 would leave the room 1,200 BTU per hour short of its own estimate.
The conversion mode uses three fixed constants and nothing else: 1 kWh = 3,412.14 BTU, 1 watt = 3.41214 BTU per hour, and 1 ton of cooling = 12,000 BTU per hour. The page’s own worked conversions are 10 kWh = 34,121 BTU, 1.5 tons = 18,000 BTU per hour, and 1,000 watts = 3,412 BTU per hour, and the engine agrees: converting 10 kWh gives the displayed 34,121 BTU, 1 ton gives 12,000 BTU, and 1 kWh gives 3,412 BTU (rounded for display). To go the other way, divide instead of multiplying: 34,121 BTU ÷ 3,412.14 = 10 kWh. The inverse mode divides too: room area served equals heater BTU divided by BTU per square foot, so a 12,000 BTU unit serves 600 square feet on the 20 cooling factor, but only 240 square feet on the cold-climate heating factor of 50 — and a 30,000 BTU heater serves 1,500 square feet at 20 but 600 at 50, as the engine confirms. The same heater serves very different rooms depending on the factor, which is why the factor is a choice on the page rather than a hidden constant.
Rate versus energy: the distinction the whole page turns on
The most persistent confusion in heating and cooling numbers is between a rate and an amount, and this page is built around keeping them apart. BTU per hour, watts and tons are rates: they describe how fast heating or cooling happens, like the speed of a car. BTU and kWh are amounts of energy: they describe how much was used in total, like the distance the car travelled. A bill talks about kWh because it charges for energy over time; a unit label talks about BTU or tons because it rates the speed the unit can sustain. Dividing a rate by time or multiplying an amount by time does not convert one into the other — only the locked constants do, and only between the units the page lists.
That distinction explains two things people get wrong. First, a 12,000 BTU per hour air conditioner does not “use 12,000 BTU” in any fixed sense: run for one hour at full tilt it moves roughly 12,000 BTU of heat, run for ten hours it moves roughly ten times that, and run at part load it moves less — the rating is a rate, and the energy depends on how long and how hard it runs. Second, a ton of cooling is not a weight. It is a cooling capacity rating equal to 12,000 BTU per hour, so 1.5 tons is 18,000 BTU per hour and 2 tons is 24,000, and the page’s converter treats tons as a rate unit throughout, labelling rate results per hour. Anyone shopping by tons alone without checking the BTU per hour figure is shopping by a nickname for the same number — useful shorthand, but no substitute for the number itself.
The page’s hint in the conversion panel states the rule compactly: watts and tons are rates (per hour); BTU and kWh are amounts of energy; the converter turns the number itself between the four units, and the results label rate units per hour. Keep that sentence in mind whenever a figure looks wrong by a factor of time: if you converted a rate and expected an amount, or an amount and expected a rate, the constant was right and the question was wrong. And when a bill and a label seem to disagree — the bill in kWh, the label in BTU or tons — they are not disagreeing at all; they are answering different questions about the same machine, one about how fast it works and one about how much energy that work consumed.
Why 20 BTU per square foot is only a starting point
The 20 BTU per square foot figure is a widely published rule of thumb for a typical room with standard ceilings and average insulation. It ignores the things that actually decide cooling load: how well the room is insulated, how big and sun-facing the windows are, how many heat-producing appliances run in it, and how hot the local climate gets. Two 500 square foot rooms can honestly need sizes thousands of BTU apart — one shaded, well insulated and mild-climate, the other sun-facing, glass-walled and in a hot climate — and no rule of thumb can tell them apart, because the rule sees only the floor area. The page’s own adjustments for sun, kitchen, ceiling height and people are a start at seeing more than area, but they are still only four adjustments, and insulation, windows and climate are not among them.
That is why the page’s advice is consistent on every mode: use this page to narrow the range, then let a professional Manual J calculation settle the purchase. Manual J is the industry calculation that accounts for insulation, windows, shading, orientation and climate — the exact factors the rule of thumb omits — and it is the difference between a size that is roughly right and a size that is right for the room in question. An oversized unit is not a safe error either: it cools too fast, cycles on and off, and leaves humidity behind, while an undersized unit simply cannot keep up on the hottest day. The rounding-up step to the nearest standard size is the page’s only deliberate oversizing, and it is small — from 11,200 to 12,000 in the four-person case — not a licence to buy the next size up “to be safe”.
Used within those limits, the rule of thumb is genuinely useful. It tells you whether you are shopping in the 10,000 or the 24,000 range, whether a kitchen changes the answer more than a sunny window does (it does — 4,000 flat against a 10 percent uplift), and whether a heater you already own can serve a room at all (divide its BTU by the factor and see). What it cannot tell you is the exact size for a specific room, and any page that claims otherwise from floor area alone is selling certainty it does not have. The honest output of this calculator is a narrowed range with the adjustments shown separately, so you can see exactly what changed your number — and then hand that range to a professional for the final figure.
Heating factors deserve their own paragraph, because the inverse mode’s factor list is where cooling logic and heating logic most often get swapped. The page offers four factors: 20 for the cooling rule of thumb, 30 for mild-climate heating, 40 for average heating, and 50 for cold climate or poor insulation. The same 30,000 BTU heater serves 1,500 square feet at the cooling factor of 20, 1,000 at the mild-climate heating factor of 30 (30,000 ÷ 30), 750 at the average heating factor of 40, and 600 at the cold-climate factor of 50. Each step up in factor is a step up in assumed heating need per square foot, and each step shrinks the room the heater can serve — by a third from 20 to 30, by half from 20 to 40, and by three-fifths from 20 to 50. Picking the cooling factor for a heating question overstates the room served by two and a half times at the cold-climate end, which is the difference between a heater that copes and one that does not on the coldest night.
The same factor logic runs in reverse for sizing: a room that needs cooling at 20 BTU per square foot needs heating at a higher factor in any climate where heating is the harder job, and the page’s sizing mode is a cooling rule of thumb, not a heating sizer. Do not size a heater by running the cooling calculation and relabelling it: the cooling estimate for a 500 square foot room is 10,000 BTU per hour, but the heating need for the same room at the average heating factor of 40 would be 20,000 BTU per hour (500 × 40), and at the cold-climate factor of 50 it would be 25,000. Those heating figures are the inverse mode’s arithmetic applied forward — area times factor — and they show why a heater bought on cooling numbers alone will be undersized for winter in any climate colder than mild. For heating, start from the factor that matches the climate and the insulation, not from the cooling answer.
One last distinction that prevents a whole class of shopping errors: the standard size list tops out at 60,000 BTU per hour, described on the page as the largest common residential size, and the scale graphic runs from 0 to 60,000 for the same reason. A computed size above 60,000 — a very large room, or several rooms treated as one — is the page telling you, indirectly, that you are no longer shopping for a single residential unit. Zoning the space, splitting it across two units, or getting a professional sizing for a multi-room system are all better answers than hunting for a single unit larger than the residential range, and the page’s refusal to offer a larger standard size is a hint, not a limitation. If the calculator’s answer leaves the top of its own scale, believe the scale: the job has outgrown the tool, and a professional calculation for the whole space is the next step, not a bigger box.
Ceiling height deserves a final worked note, because it is the adjustment people most often apply twice or not at all. The rule is 10 percent per foot above 8 feet, applied to the base — not compounded foot on foot, and not applied to the already-adjusted figure. The default room at 10 feet is 12,000 BTU per hour: the 10,000 base plus two feet at 10 percent each, which is 2,000, not 10,000 multiplied by 1.10 twice (which would give 12,100). The difference is small on two feet and grows with height, so apply the rule as the page states it: count the feet above 8, multiply by 10 percent, and add that percentage of the base once. A room with a 12-foot ceiling, by the same rule, would be the base plus 40 percent — 14,000 BTU per hour for the default room — before sun, kitchen or people are considered at all.
People, similarly, are counted only beyond the first two: the default room already assumes two occupants, so a room with two people needs no adjustment, a room with four needs two extra people at 600 BTU per hour each (1,200, giving the verified 11,200), and a room with one person does not get a discount for the empty chair. The baseline of two is built into the 20 BTU per square foot rule itself, which assumes a normally occupied room; the adjustment exists for gatherings, classrooms and busy kitchens, not for deducting the heat of someone who is not there. Counting all four occupants in a four-person room — 2,400 instead of 1,200 — would double-count the two the rule already includes, and would push the computed size to 12,400 instead of the correct 11,200, rounding to a standard size a step higher than the room needs.
Sizing by room, and why the adjustments are the sizing
Start with 20 BTU per square foot at 8-foot ceilings, then adjust. Two rooms of the same area can need very different sizes — a shaded bedroom and a west-facing kitchen are different heat loads.
The baseline is floor area times 20 BTU per square foot. A 12 by 12 foot room is 144 square feet, so 2,880 BTU, served in practice by a 5,000 BTU unit, the smallest standard size. A 20 by 15 foot room is 300 square feet, so 6,000 BTU, a 6,000 to 8,000 BTU buy depending on exposure. The adjustments then do the real work: scale by ceiling height divided by 8, add about 10% for strong sun, subtract about 10% for heavy shade, add about 600 BTU per person beyond two, and add 4,000 BTU for a kitchen. A 300-square-foot kitchen-dining room with 10-foot ceilings, west sun, and four occupants reaches about 13,450 BTU from a 6,000 BTU baseline — the same area as a shaded bedroom, double the load.
One ton of cooling is 12,000 BTU per hour, so an 18,000 BTU system is 1.5 tons and 24,000 BTU is 2 tons. Buy the standard size at or just above the adjusted figure, not two sizes up: an oversized unit short-cycles, shuts off before removing humidity, and leaves the room cold and clammy while wearing the compressor. Mini splits are sized by zone, one head per room, each sized to its own room, with the smallest head at 9,000 BTU and an inverter compressor that tolerates the oversize a small room implies. The companion guide works the sizing table, every adjustment with a worked example, the tonnage conversion, the mini-split zone method, window versus portable units, and heating, which uses a different rate — about 30 BTU per square foot in hot climates, 40 in moderate climates, and 55 in cold ones.
Frequently asked questions
How many BTU do I need for a 500 sq ft room?
As a rule-of-thumb estimate, 10,000 BTU per hour: 500 sq ft times 20 BTU per sq ft. A sunny room adds 10 percent, taking it to 11,000 BTU per hour, and a kitchen adds 4,000 BTU per hour. This is only a rough estimate: for a real purchase, get a Manual J professional calculation that accounts for insulation, windows, and climate.
How do I convert BTU to kWh?
Divide BTU by 3,412.14, because 1 kWh equals 3,412.14 BTU. So 10 kWh equals 34,121 BTU, and 34,121 BTU equals 10 kWh. The same constant works in both directions.
How many BTU is one ton of cooling?
One ton of cooling equals 12,000 BTU per hour, so 1.5 tons equals 18,000 BTU per hour and 2 tons equals 24,000 BTU per hour. Ton here is a cooling capacity rating, not a weight.
How many watts is 1,000 BTU per hour?
About 293 watts, because 1 watt equals 3.41214 BTU per hour. Divide BTU per hour by 3.41214 to get watts, or multiply watts by 3.41214 to get BTU per hour.
Is the room-size result exact?
No. Every room-size result on this page is a rule-of-thumb estimate built on 20 BTU per sq ft plus simple adjustments. Insulation, ceiling height, windows, climate, and shading all change the real number, so treat the result as a starting point and ask a professional for a Manual J calculation before buying.
What size room can a 12,000 BTU heater serve?
On the 20 BTU per sq ft cooling rule of thumb, 12,000 BTU serves about 600 sq ft. For heating, this page also offers 30, 40, and 50 BTU per sq ft factors, which give 400, 300, and 240 sq ft for the same 12,000 BTU. Colder climates and poor insulation need the higher factors.
Why does a sunny room need more cooling?
Because direct sun is a heat load that floor area cannot see. The page multiplies the base by 1.10 for a sunny room, taking the default 500 sq ft room from 10,000 to 11,000 BTU per hour. The uplift is proportional — 10 percent of whatever the base is — so on a 1,000 sq ft room it would add 2,000 BTU per hour rather than 1,000. A shaded room with the same floor area genuinely needs less, which is one reason two identical rooms can honestly need sizes thousands of BTU apart.
If my room is 1,000 sq ft, do I just double the 500 sq ft figure?
For the rule-of-thumb base, yes: 1,000 square feet at 20 BTU per square foot is 20,000 BTU per hour, exactly double the default 10,000, before any adjustment. The adjustments then apply to the new base — a sunny 1,000 sq ft room would be 22,000 by the same 1.10 multiplier, and a kitchen would still add a flat 4,000. Doubling works because the base is area times a fixed factor; it stops working the moment a professional Manual J calculation replaces the rule of thumb with the room’s actual insulation, windows and climate.
What is the difference between a BTU and a BTU per hour?
A BTU is an amount of energy; a BTU per hour is a rate. A 12,000 BTU per hour air conditioner moves heat at that rate while it runs — roughly 12,000 BTU in one hour at full tilt, roughly ten times that in ten hours. Bills charge for amounts (kWh), labels rate machines (BTU per hour, watts, tons), and the converter on this page keeps the two apart: 1 kWh equals 3,412.14 BTU of energy, 1 watt equals 3.41214 BTU per hour of rate, and 1 ton of cooling equals 12,000 BTU per hour of rate.
Why does the same heater serve different room sizes?
Because the area served is the heater’s BTU divided by the BTU-per-square-foot factor, and the factor is a choice, not a constant. A 12,000 BTU unit serves 600 square feet on the 20 cooling factor but only 240 square feet on the cold-climate heating factor of 50, and a 30,000 BTU heater serves 1,500 square feet at 20 but 600 at 50. The colder the climate assumption, the more heating power each square foot is assumed to need, and the smaller the room the same heater can serve. Heating factors are planning guides, not guarantees.
What size air conditioner do I need for a 300 square foot room?
About 6,000 BTU per hour by the baseline rule, 300 times 20, before adjustments. With strong sun or poor insulation that rises to 6,600 to 6,900 BTU, so an 8,000 BTU window or portable unit is the usual buy, while a shaded, well-insulated room is served by a 6,000 BTU unit. Add 4,000 BTU if the room is a kitchen, and scale for ceilings above 8 feet.
How many BTU is a 1.5 ton air conditioner?
18,000 BTU per hour, since one ton is 12,000 BTU per hour. A 9,000 BTU unit is three quarters of a ton, 12,000 BTU is 1 ton, 24,000 BTU is 2 tons, and 36,000 BTU is 3 tons. Mini splits and central systems are sold in tons, window units in BTU, so divide the BTU requirement by 12,000 to convert.
Can an air conditioner be too big for a room?
Yes, and oversizing is worse than a small undersize. An oversized unit cools the air fast and shuts off before it has run long enough to remove humidity, leaving the room cold and clammy, and the constant on-off cycling wears the compressor and wastes electricity. Size to the calculated load, or one standard size up when between sizes in a hot climate. Inverter mini splits tolerate sizing error better than fixed-speed units.
Related calculators
Disclaimer: room-size results on this page are rule-of-thumb estimates only and are not a substitute for a Manual J professional calculation. Actual sizing depends on insulation, windows, ceiling height, shading, climate, and usage. This page recommends no specific air conditioner model and uses no manufacturer data. Energy and cost figures are estimates for planning only.
↑